This option allows the BMS to turn the multi-purpose output OFF whenever a critical fault code is set.
Critical fault codes are defined by the following: P0A06 / P0A07 (a charge / discharge enforcement fault is detected), P0AC0 (a problem with the current sensor is detected), and P0A04 / P0AFA / P0A01 / P0A03 (a critical voltage sensing fault is detected). If multiple units are connected in series (Master / Slave) then a multi-unit communication failure will also trigger this condition. The output will re-engage once these fault codes are cleared. Other non-critical faults (such as thermistor fault, high voltage isolation fault, etc) will NOT cause this output to turn off.
NOTE: This option is NOT affected by the "Invert Multi-Purpose Output Polarity" option. If this option is enabled then the multi-purpose output signal will always be turned OFF in the event of a critical fault code being set.
< Invert Multi-Purpose Output Polarity | Pack Amphours > |