This option will invert the output polarity of the multi-purpose output signal. This means that if the output is normally OFF it would then become normally ON if this option was enabled.
NOTE: The multi-purpose output status in the BMS utility reflects whether the signal is activated (ON) or not. It does not reflect whether the signal output is actually low or high (eg: if the signal is ON but the multi-purpose output inverted option is enabled, the signal will still show ON in the BMS utility even though the output is low due to the inversion)
NOTE: This option does NOT alter the behavior of the Turn MPO Off If Critical Fault option. This means that the relay output will always turn OFF (disengage) if a critical fault occurs regardless of whether this option is enabled.